550T-101X141-501 Split Core Transformer
Electromagnetic Ind.Indoor, Model: 550, Ratio: 500:5 A, Single Phase, 10 kV BIL, 60 Hz, Single Ratio, Metering Class: 2.4 B0.1
500T-041X117-502 Split Core Transformer
Electromagnetic Ind.Indoor, Model: 500, Ratio: 5000:5 A, Single Phase, 10 kV BIL, 60 Hz, Single Ratio, Metering Class: 1% 30 VA, Rating Factor: 1.33
500T-041X071-601 Split Core Transformer
Electromagnetic Ind.Indoor, Model: 500, Ratio: 600:5 A, Single Phase, 10 kV BIL, 60 Hz, Single Ratio, Metering Class: 5% 2 VA
500T-041X071-801 Split Core Transformer
Electromagnetic Ind.Indoor, Model: 500, Ratio: 800:5 A, Single Phase, 10 kV BIL, 60 Hz, Single Ratio, Metering Class: 5% 2 VA
500T-041X117-302 Split Core Transformer
Electromagnetic Ind.Indoor, Model: 500, Ratio: 3000:5 A, Single Phase, 10 kV BIL, 60 Hz, Single Ratio, Metering Class: 1% 25 VA, Rating Factor: 1.33
500T-041X117-252 Split Core Transformer
Electromagnetic Ind.Indoor, Model: 500, Ratio: 2500:5 A, Single Phase, 10 kV BIL, 60 Hz, Single Ratio, Metering Class: 1% 25 VA, Rating Factor: 1.33
500T-041X117-122 Split Core Transformer
Electromagnetic Ind.Indoor, Model: 500, Ratio: 1200:5 A, Single Phase, 10 kV BIL, 60 Hz, Single Ratio, Metering Class: 1% 10 VA, Rating Factor: 1.33
500T-041X071-401 Split Core Transformer
Electromagnetic Ind.Indoor, Model: 500, Ratio: 400:5 A, Single Phase, 10 kV BIL, 60 Hz, Single Ratio, Metering Class: 5% 2 VA
500T-041X071-501 Split Core Transformer
Electromagnetic Ind.Indoor, Model: 500, Ratio: 500:5 A, Single Phase, 10 kV BIL, 60 Hz, Single Ratio, Metering Class: 5% 2 VA
500T-041X071-402 Split Core Transformer
Electromagnetic Ind.Indoor, Model: 500, Ratio: 4000:5 A, Single Phase, 10 kV BIL, 60 Hz, Single Ratio, Metering Class: 1% 35 VA
500T-041X071-152 Split Core Transformer
Electromagnetic Ind.Indoor, Model: 500, Ratio: 1500:5 A, Single Phase, 10 kV BIL, 60 Hz, Single Ratio, Metering Class: 5% 2 VA
500T-041X071-102 Split Core Transformer
Electromagnetic Ind.Indoor, Model: 500, Ratio: 1000:5 A, Single Phase, 10 kV BIL, 60 Hz, Single Ratio, Metering Class: 5% 2 VA
Electromagnetic Ind. 19SHT-301
Electromagnetic Ind.Indoor, Model: 19, Ratio: 300:5 A, Single Phase, 10 kV BIL, 60 Hz, Single Ratio, Metering Class: 0.6 B0.1, Rating Factor: 2.0, Window Diameter: 4.25
Electromagnetic Ind. 170SHT-102
Electromagnetic Ind.Indoor, Model: 170, Ratio: 1000:5 A, Single Phase, 10 kV BIL, 60 Hz, Single Ratio, Metering Class: 0.3 B0.5, Rating Factor: 1.33, Window Diameter: ...
View full detailsElectro-Meters CT1-SC201 200:5
Electro-MetersSplit Core Current Transformer Window Size: 1.00" Ratio 200:5 600V c/w 36" lead wire cURus, CATIV, CE
Accuenergy AcuCT-75-200:333
Accuenergy200A:333mV Split Core CT, Window 0.75 x 0.75
Accuenergy AcuCT-2031-600:5
Accuenergy600:5A Split Core CT, Window 2.0 x 3.15
Accuenergy AcuCT-H040-20:333
Accuenergy20A:333mV Hinged CT, Window 0.4"
Accuenergy AcuCT-3147-1000:5
Accuenergy1000:5A Split Core CT, Window 3.15 x 4.72
Accuenergy AcuCT-H100-100:333
Accuenergy100A:333mV Hinged CT, Window 1"
Accuenergy AcuCT-125-400:333
Accuenergy400A:333mV Split Core CT, Window 1.25 x 1.25
Accuenergy AcuCT-2031-800:5
Accuenergy800:5A Split Core CT, Window 2.00 x 3.15