Transformers & Switches
Filters
GE / ITI 456-600-230
GE / ITIPotential Transformer 2.608:1 Ratio Accuracy 0.3% 25VA 60Hz CSA/UR Approvals
2DT-301-1 300:1
Electromagnetic Ind.Current Transformer Toroidal, donut style 600V Class 300:1 Ratio 50-400Hz .92" Window size
Veris Industries HAWKEYE H800
Veris IndustriesCurrent Switch: 0.25-200 Amperage Range Normally Open 1.0A@30VAC/DC Status Output 0.25A or less Fixed Trip Point Mini Solid-Core Housing UL Listed ...
View full detailsVeris Industries HAWKEYE H921
Veris IndustriesCurrent Sensor 4-20mA Analog Output 0-30/60/120A field selectable Amp Range Split-Core Housing UL Listed for use on 75 deg. insulated conductors
Veris Industries HAWKEYE H931
Veris IndustriesHawkeye 931 Split-Core 4-20mA Output Loop-Powered Current Transducers with Patented Integral Command Relay, Amp Range 0-30/60/120A
GE / ITI AL-400
GE / ITIIndoor, Model: A, Ratio: 40:5 A, Single Phase, 10 kV BIL, 60 Hz, Single Ratio, Metering Class: 3% 1.5 VA, Rating Factor: 1.0, Window Diameter: 1.05
Canadian Shunt LA-50-50
Canadian ShuntDC AMMETER SHUNT, 50 ADC / 50 mV
Canadian Shunt C-300-50
Canadian ShuntDC AMMETER SHUNT, 300 ADC / 50 mV
Canadian Shunt C-400-100
Canadian ShuntDC AMMETER SHUNT, 400 ADC / 100 mV
Canadian Shunt C-25-100
Canadian ShuntDC AMMETER SHUNT, 25 ADC / 100 mV
Canadian Shunt C-150-100
Canadian ShuntDC AMMETER SHUNT, 150 ADC / 100 mV
Canadian Shunt C 1-100
Canadian ShuntDC AMMETER SHUNT, 1 ADC / 100 mV
GE / ITI 8SHT-202
GE / ITIIndoor, Model: 8, Ratio: 2000:5 A, Single Phase, 10 kV BIL, 60 Hz, Single Ratio, Metering Class: 0.3 B0.9, Rating Factor: 1.0, Window Diameter: 3.25
GE / ITI 8SHT-301
GE / ITIIndoor, Model: 8, Ratio: 300:5 A, Single Phase, 10 kV BIL, 60 Hz, Single Ratio, Metering Class: 0.6 B0.2, Rating Factor: 2.0, Window Diameter: 3.25
GE / ITI 460-346
GE / ITIIndoor, Ratio: 346:120, Single Phase, 10 kV BIL, 60 Hz, Metering Class: 0.6 W
GE / ITI 2VT469-480
GE / ITIIndoor, Ratio: 480:120, Single Phase, 10 kV BIL, 60 Hz, Metering Class: 1% 5 VA
GE / ITI 8RL-801
GE / ITIIndoor, Model: 8, Ratio: 800:5 A, Single Phase, 10 kV BIL, 60 Hz, Single Ratio, Metering Class: 0.3 B0.5, Rating Factor: 1.50, Window Diameter: 3.25
GE / ITI 7RL-401
GE / ITIIndoor, Model: 7, Ratio: 400:5 A, Single Phase, 10 kV BIL, 60 Hz, Single Ratio, Metering Class: 1% 15 VA, Rating Factor: 1.0, Window Diameter: 2.5
7RL-102-1
Electromagnetic Ind.Indoor, Model: 7, Ratio: 1000:1 A, Single Phase, 10 kV BIL, 60 Hz, Single Ratio, Metering Class: 1% 25 VA, Window Diameter: 2.5
GE / ITI 781-601MR
GE / ITIIndoor, Model: 781, Ratio: 600:5 A, Single Phase, 10 kV BIL, 60 Hz, Multi Ratio, Relay Class: C100, Metering Class: 0.3 B0.5, Rating Factor: 2.0, W...
View full detailsGE / ITI 780-601
GE / ITIIndoor, Model: 780, Ratio: 600:5 A, Single Phase, 10 kV BIL, 60 Hz, Single Ratio, Metering Class: 0.3 B0.9, Rating Factor: 2.0, Window Diameter: 6....
View full detailsGE / ITI 780-401
GE / ITIIndoor, Model: 780, Ratio: 400:5 A, Single Phase, 10 kV BIL, 60 Hz, Single Ratio, Metering Class: 0.3 B0.2, Rating Factor: 2.0, Window Diameter: 6....
View full details613-401 Split Core Transformer
Electromagnetic Ind.Indoor, Model: 613, Ratio: 400:5 A, Single Phase, 10 kV BIL, 60 Hz, Single Ratio, Metering Class: 2% 3 VA, Rating Factor: 1.33
GE / ITI 5SFT-501
GE / ITIIndoor, Model: 5, Ratio: 500:5 A, Single Phase, 10 kV BIL, 60 Hz, Single Ratio, Metering Class: 1% 20 VA, Rating Factor: 1.0, Window Diameter: 1.56